San copy is a neat bit of software that emc or dg, i forget which developed to rip data off. Chapter 2 introduces naviseccli and navicli commands. Install vnx cli for the splunk addon for emc vnx splunk. About the splunk addon for emc vnx source types for the splunk addon for emc vnx release notes for the splunk addon for emc vnx release history for the splunk addon for emc vnx hardware and software requirements for the splunk addon for emc vnx. Chapter 3 explains the basic cli commands, that is, those that. So now ive bound the luns, i can use another command to give them a label that. Naviseccli is a tool used for accessing the vnx using cli. Create a session to upgrade the system software, uemcli d 10. Emc navisphere command line interface cli reference. To have san copy search all targets for devices and log the devices it finds in the logs run the following command naviseccli h user password scope 0 sancopy verify wwn 10. How to gather spcollect files or logs for emc vnx or clarrion series array.
Adding the security files to naviseccli is recommended to avoid login commands at the beginning of other commands for e. You can retrieve the file from the system using the managefiles command. Navisphere cli is a command line interface tool provided by emc for accessing and managing vnx or clariion storage arrays. The naviseccli command initiates the copying of data from a failing disk to an existing hot spare while the original disk is still functioning. Unmark operation in an unmark operation, san copy destroys the snapshot that was created during the mark operation, discarding any changes. The splunk addon for emc vnx uses naviseccli to collect data from the array. Some degree of security is provided by the privileged user list, which can be configured to limit the users and ip addresses that can manage the array. Emc vnx driver supports storageassisted volume migration, when the user starts migrating with cinder migrate forcehostcopy false or cinder migrate, cinder will try to leverage the vnxs native volume migration functionality. The most uptodate information about the emc san copy software is posted on. Once the copy is made, the failing disk will be faulted and the hotspare will be activated. X reference for basic and access logix commands pn 069001038 rev a06.
How to gather spcollect files or logs for emc vnx or. How do i retrieve navisphere analyzer files using naviseccli. Cli commands for the emc san copy software are explained in the san copy cli manual. Do we use different commands or just use the same commands for step 3 and. Emc storage set loginpassword via naviseccli command. This post is designed to help quickly find the general syntax of uemcli commands and be short enough to print out a copy. Navisphere cli is a command line interface tool for emc storage. They are divided up into categories for zoning, show, port, timedate, license, banner, password, snmp, user config, firmware, and miscellaneous. The naviseccli spcollect command selects a collection of system log files and places them in a single. Navisphere cli can also be leveraged for automating management tasks through scripts or batch files. Navicli originally known as classic cli is over 10 years of old. Emc san cli administrators guide command line interface. Executive summary emc san copy is an optional software application. Select properties from the menu and go to the software tab.
The remaining cli commands are webbased and are provided with the software that. Celerra vnx file replication job creation errors when selecting destination. It can also be used to automate the management functions through shell scripts and batch files. Im probably going to plink over from powershell and run a few commands on the vnx box to process and integrate our storage info. This is a list of useful brocade cli commands that i keep at my desk for reference. How to compile capacity and used capacity of an emc vnx via cli. The following command initiates a software upgrade that pauses after the first sp reboots. You can use it for storage provisioning and manage array configurations from any one of the managed storage system on the lan. Clariion, cx4, emc, naviseccli, san, storage, storage. Now if you select the san copy luns tab you will see this, i know it looks as if we. The cli folder may already be in the path statement, in which case, the commands can be run from any directory.
Cli commands for the emc mirrorview software are explained in the mirrorview cli manual and cli commands for emc snapview for both. How to compile capacity and used capacity of an emc vnx. I\m posing this question to myself and answering it here, as i want a record of the information. This typeface indicates text including pu nctuation that you type verbatim, all commands, pathnames, filenames, and directory names.
Emc controlcenter navisphere command line interface cli. Emc vnx batch enabler installation by software suite. For details on all of the specific options for each of these commands i recommend downloading the 612 page long dell emc cli reference guide. Emc san copy is arraybased software that runs on a dell emc array.
Then, on this host, you can enter cli commands to any storage system on which you have an account that matches the. How do i download and install the navisphere cli tool to. Unfortunately native snapview clone software will not allow you to create clone. Were running these commands against cx4 arrays running the latest r30 flare. Run the following navisphereunisphere command line interface cli command these commands where added to cli version r28 and higher and work for cx4 and vnx. Dell emc vnx block storage navicli data collector netapp. Therefore, some functions described in this manual may not be.
Emc san copye command line interfaces reference vii preface finding current information the most uptodate information about the emc san copye software is posted on the emc powerlink website. In case the pdf goes away, i have reproduced most of it below, minus some of the screenshots. Emc navisphere command line interface cli reference ix preface as part of an effort to improve and enhance the performance and capabilities of its product line, emc from time to time releases revisions of its hardware and software. Most of these can also be performed using navisphere manager gui. Generalcommandsfornavispherecli emc cli naviseccli user name password scope 0 address 10. The san guy is a professional information technology blog covering a wide range of. Hence, i use ps commands to convert the output to a structured format for parsing to html for generating report. Learn vocabulary, terms, and more with flashcards, games, and other study tools. About dell careers community events partner program premier dell technologies. Supports resignaturing the copy of a vmfs volume, and mounting and unmounting the copy. The navisphere cli version must match the firmware version on the controller. The commands that will invoke naviseccli are mirrorview, snap view except clonerelated commands, sancopy, getall, and set feature feature rm where rm stands for remote mirror.
The navisphere cli runs on a management host that communicates with the storage system. I have two netra machines that connected to emc storage emc flare 28 i installed solaris 10 on both netra machines my question is it possible to set the login and password for emc storage. Emc navisphere cli command examples with naviseccli it. The getall command has been modified to display snapview, san copy. Vnx how to download the naviseccli how to manage the. The following sets of commands are run to change the cache options in the clariion cx, cx3 and cx4 systems using navicli. Please clarify are these steps good for an online incremental san copy. Chapter 2 explains the naviseccli and analyzer cli commands for monitoring storagesystem performance. Rem start the script from where the naviseccli executable is stored cd c. Before configuring this data source, make sure that the emc navisphere cli is installed on the target device and on the insight server. The vnx cinder driver performs the volume operations by executing navisphere cli naviseccli which is a commandline interface used for management, diagnostics, and reporting functions for vnx.
A user explicitly initiates the operation as desired. Notice also that mat has started using as his password too. There are two simple ways to check the release of your flare operating environment. Classic cli does not support user authentication or navisphere roles. Emc controlcenter navisphere command line interface cli version 6. Use, copy, and distribution of any emc software described in this publication require an applicable software. Administrators can issue commands for general array management, including storage provisioning, status, and configuration control. The navicli command or naviseccli if you have the ssl version allows you to query and configure an emc clariion array, it can be much quicker to use than the java gui with the cx3 and cx4s, and of course it allows you to automate operations creating hundreds of luns is now not a problem. Navisphere analyzer command line interface cli reference. Emc vnx driver openstack configuration reference liberty. Navisphere cli is a tool provided by emc to provide for programmatic management of block san storage systems such as clariion and vnx series. Entry and midrange storage enterprise storage allflash storage softwaredefined storage storage management and networking cloud. When you install new sp software using the cli, the only way to determine when the installation is finished is to issue periodic ndu status commands until the cli shows the operation is completed. Emc vnx driver interacts with configured vnx array.
Ive recently completed a project to replace an old cx4120 with a newer vnx series san. Using san copy to migrate data to clariion storage systems dell. Navisphere cli is a command line interface tool for emc storage system management. The san copy software automatically invokes the mark operation during initial synchronization and at the beginning of an incremental update operation. Whether this behaves differently on the vnx or not, im not sure. Verify that the device and the host are both running identical versions of the software. You can expand a lun or metalun in two ways stripe. Only the nas is linuxbased other than some vm guest oses.
I am running a windows system, storing and running commands from various directories on the c. When you have a long password this can lead to some. The naviseccli command sends system management and configuration. Emc charge an arm and a let for their sanitisation process, so after looking into the process i decided to go about it myself. Finding the download to get the software can be though. Fast cache and naviseccli posted on june 30, 20 by admin fast fully automated storage tiering cache as all you know is a new feature introduced with clariion falre r30 and vnx systems, in which we are making use of high speed flash drives to be configured as cache. For performance data collection, statistics logging must be turned on. Navisphere manager to configure and run the san copy software. The logicmonitor collector uses this tool to gather data directly from the emc service processors. Cli commands for many functions are server based and are provided with the host agent. Use the navisphere gui and right click on the array icon inside navisphere. Emc configure the reserved lun pool with naviseccli.
134 113 360 439 1146 478 102 872 585 1004 47 420 633 530 484 1306 1239 368 1189 90 1591 1301 176 1490 473 913 262 812 169 1093 640 1213 436 613 1366 542 1259 777 1049 179 47 333 567 1071 199 1096 1082